Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
cs:sw:01-mervis:mervis-scada-project-hidden [2021/04/28 07:00]
avsetula
cs:sw:01-mervis:mervis-scada-project-hidden [2024/04/03 09:45] (current)
avsetula [2 Nastavení PLC]
Line 1: Line 1:
 <​html><​div class="​version-switch">​ <​html><​div class="​version-switch">​
-  <a href="#​zalozeni_projektu_mervis_scada"><​div class="​actual-version">​IDE v2.4.0</​div></​a>​+  <a href="#​zalozeni_projektu_mervis_scada"><​div class="​actual-version">​IDE v2.4.0 ​a novější</​div></​a>​
   <a href="/​cs:​sw:​01-mervis:​mervis-scada-project-v230-hidden"><​div>​IDE v2.3.0</​div></​a>​   <a href="/​cs:​sw:​01-mervis:​mervis-scada-project-v230-hidden"><​div>​IDE v2.3.0</​div></​a>​
 </​div></​html>​ </​div></​html>​
Line 10: Line 10:
 <WRAP half column 15%> <WRAP half column 15%>
 ;;# ;;#
-<​html><​span class="​dev-tag dev-axon">Axon</​span></​html>​ \\+<​html><​span class="​dev-tag dev-patron">Patron</​span></​html>​ \\
 <​html><​span class="​dev-tag dev-neuron">​Neuron</​span></​html>​ \\ <​html><​span class="​dev-tag dev-neuron">​Neuron</​span></​html>​ \\
-<​html><​span class="​dev-tag dev-unipi11">​Unipi&​nbsp1.1</​span></​html>​+<​html><​span class="​dev-tag dev-gate">​Gate</​span></​html>​ \\ 
 +<​html><​span class="​dev-tag dev-unipi11">​Unipi&​nbsp1.1</​span></​html>​ \\ 
 +<​html><​span class="​dev-tag dev-axon">​Axon</​span></​html>​
 ;;# ;;#
 </​WRAP>​ </​WRAP>​
Line 19: Line 21:
 V následujícím článku se dozvíte, jak vytvořit projekt pro Mervis SCADA pro nové nebo již nasazené řešení v Mervis IDE. V následujícím článku se dozvíte, jak vytvořit projekt pro Mervis SCADA pro nové nebo již nasazené řešení v Mervis IDE.
  
- +<WRAP center round box> 
-==== Co budete potřebovat? ​====  +<​html><​span class="​kbBlue-H4alt">​Co budete potřebovat?​</​span></​html>​ 
-  * [[https://​www.unipi.technology/​cs/axon-c20 | Jednotku Unipi]] s alespoň [[cs:​files:​software:​os-images:​00-start|Mervis OS v2.2.0]] a [[cs:​files:​software:​mervis:​00-start|Mervis IDE v2.3.0]] +  * [[https://​www.unipi.technology/​patron-c44 | Jednotku Unipi]] s alespoň [[cs:​files:​software:​os-images:​00-start|Mervis OS v2.2.0]] a [[cs:​files:​software:​mervis:​00-start|Mervis IDE v2.4.0]] 
-  * Připojení k internetu+  * Trvalé připojení k internetu ​pro jednotku
   * Platný účet s aktivovanou licencí na [[https://​www.unipi.technology/​cs/​getmervis|webových stránkách Unipi]]   * Platný účet s aktivovanou licencí na [[https://​www.unipi.technology/​cs/​getmervis|webových stránkách Unipi]]
 +</​WRAP>​
 +
 +
 +===== Úprava po převodu z Mervis IDE v2.3.0 =====
 +Pokud převádíte projekt z verze IDE 2.3.0, je třeba nastavit [[#​plc-profil-historie|PLC profil historie]], který byl ve verzi IDE 2.3.0 nastaven u terminálu SCADA. Nyní se tento profil historie nastavuje pro každý přiřazený kontrolér zvlášť.
 +
 +Dále je nutné, v tabulce datových bodů, označit datové body pro které ukládáte historii v databázi a následně zvolit v pravém sloupci položku "​Přiřazené profily historie"​. Více je popsáno v kapitole [[#​pridani_datovych_bodu_do_mervis_db|3.3 Přidání datových bodů do Mervis DB]].
  
  
Line 52: Line 61:
 S IDE projektem pracujete ve vývojovém rozhraní Mervis IDE. Abyste mohli PLC nakonfigurovat,​ nebo naprogramovat,​ vytvoříte si “projekt” do kterého PLC přidáte. Více popsáno [[creating-new-project-hidden|zde v odkazu]]. S IDE projektem pracujete ve vývojovém rozhraní Mervis IDE. Abyste mohli PLC nakonfigurovat,​ nebo naprogramovat,​ vytvoříte si “projekt” do kterého PLC přidáte. Více popsáno [[creating-new-project-hidden|zde v odkazu]].
  
-==== 1.1 Jak to celé funguje ​dohromady ​====+==== 1.1 Jak to dohromady ​celé funguje ====
 Mervis SCADA je aplikace běžící na serverech Unipi a pro komunikaci s PLC používá Mervis Proxy. Všechna PLC, která chcete zapojit do projektu tedy musí mít připojení k internetu a musí být připojena k Mervis Proxy. Pro zobrazení historie a analýzu dat v Mervis SCADA je potřeba, aby se dané proměnné z PLC ukládaly do Mervis DB. Ovládací panel SCADA a mobilní aplikace pak přistupuje přímo na Mervis SCADA a nekomunikuje s PLC napřímo. Není tedy potřeba v místě technologie řešit se správci sítě přidělení veřejných IP nebo přesměrovaní portů na firewallech. PLC také nemusí být přímo vystaveno do internetu, což zvyšuje bezpečnost celé technologie. Mervis SCADA je aplikace běžící na serverech Unipi a pro komunikaci s PLC používá Mervis Proxy. Všechna PLC, která chcete zapojit do projektu tedy musí mít připojení k internetu a musí být připojena k Mervis Proxy. Pro zobrazení historie a analýzu dat v Mervis SCADA je potřeba, aby se dané proměnné z PLC ukládaly do Mervis DB. Ovládací panel SCADA a mobilní aplikace pak přistupuje přímo na Mervis SCADA a nekomunikuje s PLC napřímo. Není tedy potřeba v místě technologie řešit se správci sítě přidělení veřejných IP nebo přesměrovaní portů na firewallech. PLC také nemusí být přímo vystaveno do internetu, což zvyšuje bezpečnost celé technologie.
  
Line 60: Line 69:
 ==== 1.2 Vytvoření projektu SCADA ==== ==== 1.2 Vytvoření projektu SCADA ====
 Prvním krokem k zapojení PLC do Mervis SCADA je vytvoření SCADA projektu v [[https://​www.unipi.technology/​cs/​customer/​scada/​|Zákaznickém portálu]]. Pro přihlášení použijte účet, přes který jste provedli nákup. ​ Prvním krokem k zapojení PLC do Mervis SCADA je vytvoření SCADA projektu v [[https://​www.unipi.technology/​cs/​customer/​scada/​|Zákaznickém portálu]]. Pro přihlášení použijte účet, přes který jste provedli nákup. ​
 +
 +<WRAP center round info 95%>
 +Pokud u nás zákaznický účet nemáte, pro jeho vytvoření se stačí registrovat na webových stránkách [[https://​www.unipi.technology/​cs/​zakaznik/​registration/​|Unipi technology]].
 +</​WRAP>​
  
 <​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​01-mervis-scada-project-cz.png)">​ <​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​01-mervis-scada-project-cz.png)">​
Line 93: Line 106:
  
 ===== 2 Nastavení PLC ===== ===== 2 Nastavení PLC =====
-V druhém kroku nakonfigurujeme PLC tak, aby k nim Mervis SCADA měla přístup. V Mervis IDE vytvořte ​nový projekt, nebo otevřete již stávající. ​Projekt ​je nutné mít v tzv. [[creating-new-project-hidden#​prepnuti_ze_zjednoduseneho_modu_na_plny_mod|Plném módu]].+V druhém kroku nakonfigurujeme PLC tak, aby k nim Mervis SCADA měla přístup. V Mervis IDE vytvořte ​novou sestavu, nebo otevřete již stávající. ​Sestavu ​je nutné mít v tzv. [[creating-new-project-hidden#​prepnuti_ze_zjednoduseneho_modu_na_plny_mod|Plném módu]].
  
-Každé PLC, které chceme ​zapojit do SCADA projektu, musí být připojené k Mervis Proxy. Pro nastavení Mervis Proxy slouží kolonka Parametry Proxy ve vlastnostech PLC. Parametry získáte ve vašem [[https://​www.unipi.technology/​cs/​getmervis|Zákaznickém portálu]]. Pro každé PLC použijte unikátní ​ProxyID. Podrobnější vysvětlení naleznete v návodu [[connecting-to-unipi-via-mervis-proxy-hidden|Připojení k PLC Unipi pomocí služby Mervis Proxy]]. +Každé PLC, které chceme ​připojit ke SCADA projektu, musí být připojené k Mervis Proxy. Pro nastavení Mervis Proxy slouží kolonka Parametry Proxy ve vlastnostech PLC. Parametry získáte ve vašem [[https://​www.unipi.technology/​cs/​getmervis|Zákaznickém portálu]]. Pro každé PLC použijte unikátní ​Proxy ID. Podrobnější vysvětlení naleznete v návodu [[connecting-to-unipi-via-mervis-proxy-hidden|Připojení k PLC Unipi pomocí služby Mervis Proxy]].
- +
-Aby se v Ovládacím panelu SCADA a v mobilní aplikaci zobrazovaly historické hodnoty proměnných v grafech, je potřeba, aby PLC ukládalo data do Mervis DB. Pro všechna PLC v rámci jednoho SCADA projektu použijte stejné přihlašovací údaje. Ty opět naleznete ve vašem [[https://​www.unipi.technology/​cs/​getmervis|Zákaznickém portálu]]. Podrobnější vysvětlení naleznete v návodu [[storing-data-to-mervis-db-hidden|Ukládání dat do Mervis DB]].+
  
 +Aby se ve webovém rozhraní a v mobilní aplikaci SCADA zobrazovaly historické hodnoty proměnných (grafy), je potřeba, aby PLC ukládalo data do Mervis DB. Společně se SCADA projektem se vygenerují také údaje Mervis DB, které jsou určeny pro všechny PLC připojené k tomuto SCADA projektu. Nastavení a ukládání do DB je podrobně vysvětleno v návodu [[storing-data-to-mervis-db-hidden|Ukládání dat do Mervis DB]].
  
 Po nastavení parametrů Mervis Proxy a Mervis DB nezapomeňte [[updating-a-runtime-configuration-hidden|nahrát konfiguraci do PLC]]. Po nastavení parametrů Mervis Proxy a Mervis DB nezapomeňte [[updating-a-runtime-configuration-hidden|nahrát konfiguraci do PLC]].
Line 123: Line 135:
 Tím jste přidali terminál pro Mervis SCADA. Na terminál je potřeba přidat všechny PLC, ke kterým má mít Mervis SCADA přístup. Rozklikněte terminál pomocí šipky vlevo od názvu a na kanál terminálu **terminalChannel** klikněte pravým tlačítkem myši. Tím jste přidali terminál pro Mervis SCADA. Na terminál je potřeba přidat všechny PLC, ke kterým má mít Mervis SCADA přístup. Rozklikněte terminál pomocí šipky vlevo od názvu a na kanál terminálu **terminalChannel** klikněte pravým tlačítkem myši.
  
-<​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​09-mervis-scada-project-cz.png)">​ +<​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​09-mervis-scada-project-cz_v240.png)">​ 
-<img src="​https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​09-mervis-scada-project-cz.png" />+<img src="​https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​09-mervis-scada-project-cz_v240.png" />
 </​figure></​html>​ </​figure></​html>​
  
Line 133: Line 145:
 </​figure></​html>​ </​figure></​html>​
  
-Otevře se seznam PLC, které jsou dostupné v daném IDE projektu. Označte ty, které chcete připojit do Mervis SCADA a potvrďte kliknutím na **OK**. Nejčastěji budete označovat všechny.+Otevře se seznam PLC, které jsou dostupné v daném IDE projektu. Označte ty, které chcete připojit do Mervis SCADA a potvrďte kliknutím na **OK**.
  
 <​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​11-mervis-scada-project-cz.png)">​ <​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​11-mervis-scada-project-cz.png)">​
Line 147: Line 159:
   * **Časová zóna:** Nastavte stejnou jakou máte ve SCADA projektu   * **Časová zóna:** Nastavte stejnou jakou máte ve SCADA projektu
   * **Doména projektu:** Okopírujte doménu ze SCADA projektu   * **Doména projektu:** Okopírujte doménu ze SCADA projektu
-  * **URL Mervis DB:** nastavte [[https://​db.unipi.technology/​dbaccess]] 
-  * **Uživatel Mervis DB a Heslo Mervis DB:** nastavte to, které jste použili pro Vaše PLC v rámci tohoto projektu 
  
-<​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​12-mervis-scada-project-cz.png)">​ +<​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​12-mervis-scada-project-cz_v240.png)">​ 
-<img src="​https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​12-mervis-scada-project-cz.png" />+<img src="​https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​12-mervis-scada-project-cz_v240.png" />
 </​figure></​html>​ </​figure></​html>​
  
Line 157: Line 167:
   * **Koncový bod:** změňte HW configuration na **Custom** ​   * **Koncový bod:** změňte HW configuration na **Custom** ​
   * Adresu zařízení ponechte **1** (dle nastavení SSCP parametrů ve vlastnostech PLC)   * Adresu zařízení ponechte **1** (dle nastavení SSCP parametrů ve vlastnostech PLC)
-  * Pokud jste neměnili uživatelské jméno a heslo pro dané PLC, ponechte hodnoty “user” a “rw”. Ověřit si můžete ve vlastnostech daného PLC v sekci Definice uživatelů -> Uživatel (plné řízení) a Definice uživatelů -> Heslo (plné řízení).+  * Pokud jste neměnili uživatelské jméno a heslo pro dané PLC, ponechte hodnoty “user” a “rw”. Ověřit si je můžete ve vlastnostech daného PLC v sekci Definice uživatelů -> Uživatel (plné řízení) a Definice uživatelů -> Heslo (plné řízení).
   * **Proxy ID** nastavte stejné, jako je ve vlastnostech daného PLC   * **Proxy ID** nastavte stejné, jako je ve vlastnostech daného PLC
  
-<​html><​span class="​kbBlueText">​Dále ​upravíme ​sekci Parametry TCP, doporučujeme používání ​šifrovaného ​připojení SSL:</​span></​html>​\\+<​html><​span class="​kbBlueText">​Dále ​je třeba upravit ​sekci Parametry TCP, doporučujeme používat šifrované ​připojení SSL:</​span></​html>​\\
   * **Adresa zařízení:​** ''​proxy.unipi.technology''​   * **Adresa zařízení:​** ''​proxy.unipi.technology''​
   * **Port:** ''​12349''​   * **Port:** ''​12349''​
   * **SSL povoleno:** True   * **SSL povoleno:** True
-  * **Validace certifikátu:​** ​standartně nastavte FALSE, více v návodu: [[ssl-certification-validation-hidden|Validace certifikátu SSL]]+  * **Validace certifikátu:​** ​nastavte FALSE 
 + 
 +/* 
 +  * **Validace certifikátu:​** standardně nastavte FALSE, více v návodu: [[ssl-certification-validation-hidden|Validace certifikátu SSL]] 
 +*/
  
 <WRAP center round tip 85%> <WRAP center round tip 85%>
-**Poznámka:​** vždy je nutné ​nastavit i ​šifrované připojení z Mervis IDE ​k PLC. Nastavením vás provede kapitola zabezpečení ​v [[cs:​sw:​01-mervis:​creating-new-project-hidden#​zabezpeceni_kontroleru|tomto návodu]].+**Poznámka:​** vždy je vhodné ​nastavit i ​šifrované připojení z Mervis IDE ​k PLC. Nastavením vás provede kapitola zabezpečení ​v [[cs:​sw:​01-mervis:​creating-new-project-hidden#​zabezpeceni_kontroleru|tomto návodu]].
 </​WRAP>​ </​WRAP>​
  
- +/* FIXME 
-/* FIXME+
 Více informací o SSL se dočtete v návodu: [[using-secured-communication-ssl-hidden|Použití SSL pro zabezpečenou komunikaci]] Více informací o SSL se dočtete v návodu: [[using-secured-communication-ssl-hidden|Použití SSL pro zabezpečenou komunikaci]]
 */ */
  
-<​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​13-mervis-scada-project-cz.png)">​ +<​html><​div class="​directTag"​ id="​plc-profil-historie"></​div></​html>​ 
-<img src="​https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​13-mervis-scada-project-cz.png" />+<​html><​span class="​kbBlueText">​Nyní už je třeba nastavit pouze sekci PLC profil historie:</​span></​html>​\\ 
 +  * **Mervis DB URL:** nastavte [[https://​db.unipi.technology/​dbaccess]] 
 +  * **Mervis DB Uživatel a Mervis DB Heslo:** nastavte údaje, použité u danného PLC ve vlastnostech PLC 
 + 
 +<​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​13-mervis-scada-project-cz_v240.png)">​ 
 +<img src="​https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​13-mervis-scada-project-cz_v240.png" />
 </​figure></​html>​ </​figure></​html>​
 +
 +
 +
 +
  
 ===== 3 Tabulka datových bodů pro Mervis SCADA ===== ===== 3 Tabulka datových bodů pro Mervis SCADA =====
Line 222: Line 244:
 </​figure></​html>​ </​figure></​html>​
  
-U digitálních (dvou nebo více stavých proměnných) je nutné ​nastavit mapování. Tj. jak se hodnota proměnné bude reprezentovat v Mervis SCADA. Reprezentace může být textová nebo číselná. Pro otevření mapování stavů klikněte na tři tečky u položky **Mapování stavů**.+U digitálních (dvou nebo více stavých proměnných) je možné ​nastavit mapování. Tj. jak se hodnota proměnné bude reprezentovat v Mervis SCADA. Reprezentace může být textová nebo číselná. Pro otevření mapování stavů klikněte na tři tečky u položky **Mapování stavů**.
  
 <​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​18-mervis-scada-project-cz.png)">​ <​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​18-mervis-scada-project-cz.png)">​
Line 273: Line 295:
  
 ==== 3.3 Přidání datových bodů do Mervis DB ==== ==== 3.3 Přidání datových bodů do Mervis DB ====
-Po uspořádání a přidání všech datových bodů do tabulky, všechny ​tyto datové body označte+Po přidání všech ​požadovaných ​datových bodů do tabulky, ​označte ​všechny datové body spadající pod jedno PLC
  
 <WRAP center round important 75%> <WRAP center round important 75%>
Line 279: Line 301:
 </​WRAP>​ </​WRAP>​
  
-<​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​25-mervis-scada-project-cz.png)">​ +<​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​25-mervis-scada-project-cz_ide240.png)">​ 
-<img src="​https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​25-mervis-scada-project-cz.png" />+<img src="​https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​25-mervis-scada-project-cz_ide240.png" />
 </​figure></​html>​ </​figure></​html>​
  
-Nyní klikněte na některou z označených položek pravým tlačítkem myšiV nabídcekterá se otevře vyberte ​**Přidat k historii**.+V případěže máte v rámci tohoto projektu jen jedno PLC, tento odstavec přeskočte a pokračujte [[#​pridat-k-historii|přidáním do historie]]Máte-li více než jedno PLCklikněte na tři tečky {{:​files:​dialog-open_button.png?​nolink|}} u parametru ​**Přiřazené profily historie**. Otevře se okno kde přiřadíte odpovídající profil historie, potvrďte tlačítkem OK. Nyní označte datové body spadající pod další PLC a postup opakujte.
  
-<​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​26-mervis-scada-project-cz.png)">​ +<​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​25a-mervis-scada-project-cz_ide240.png)">​ 
-<img src="​https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​26-mervis-scada-project-cz.png" />+<img src="​https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​25a-mervis-scada-project-cz_ide240.png"​ /> 
 +</​figure></​html>​ 
 + 
 +<​html><​div class="​directTag"​ id="​pridat-k-historii"></​div></​html>​ 
 +Dále označte všechny datové body a klikněte na některou z označených položek pravým tlačítkem myši. V nabídce, která se otevře vyberte **Přidat k historii**.  
 + 
 +//​**Poznámka:​** Pokud máte více záznamů historie, lze datové body třídit dle konkrétních požadavků a postup se tak může mírně lišit.// 
 + 
 +<​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​26-mervis-scada-project-cz_ide240.png)">​ 
 +<img src="​https://​kb.unipi.technology/​_media/​cs:​sw:​01-mervis:​26-mervis-scada-project-cz_ide240.png" />
 </​figure></​html>​ </​figure></​html>​
  
 Nyní již jsou do [[storing-data-to-mervis-db-hidden|Mervis DB]] přidány vybrané proměnné, použité v Mervis SCADA. ​ Nyní již jsou do [[storing-data-to-mervis-db-hidden|Mervis DB]] přidány vybrané proměnné, použité v Mervis SCADA. ​
-Mervis SCADA čte proměnné z Mervis DB, je proto nutné mít v PLC správně nastavené parametry pro připojení k Mervis DB.+Mervis SCADA čte proměnné z Mervis DB, je proto nutné mít v PLC také správně nastavené parametry pro připojení k Mervis DB.
  
 <WRAP center round info 90%> <WRAP center round info 90%>
-**Poznámka:​** Při úpravách ​dbtable, grafického SCADA HMI, nebo při jakékoli úpravě ve SCADA terminálu bez dalších úprav, které by zasahovaly do PLC, není nutné sestavu nahrát do PLC, ale postačí pouze kompilace. Tím se vygeneruje nová definice pro Mervis SCADA bez zásahu do PLC.+**Poznámka:​** Při úpravách ​dptable, grafického SCADA HMI, nebo při jakékoli úpravě ve SCADA terminálu bez dalších úprav, které by zasahovaly do PLC, není nutné sestavu nahrát do PLC, ale postačí pouze kompilace. Tím se vygeneruje nová definice pro Mervis SCADA bez zásahu do PLC.
 </​WRAP>​ </​WRAP>​
  
Line 375: Line 406:
 Po označení lze zobrazit graf týkající se označených hodnot. Na posledním obrázku vidíte záznam teploty z čidla zobrazený na grafu. Po označení lze zobrazit graf týkající se označených hodnot. Na posledním obrázku vidíte záznam teploty z čidla zobrazený na grafu.
 {{ :​files:​img_breakline.png?​nolink |}} {{ :​files:​img_breakline.png?​nolink |}}
-