Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
en:00-start [2021/05/14 07:34]
avsetula
en:00-start [2022/09/27 11:24]
avsetula
Line 1: Line 1:
-======%hide Knowledge Base - Unipi technology ====== +======%hide Knowledge Base - Unipi technology ====== ​    ​ 
-         ​+ 
 {{page>​00-start:​introduction-post-hidden}} {{page>​00-start:​introduction-post-hidden}}
  
Line 15: Line 15:
  
 ===== News ===== ===== News =====
 +
 +
 +== 2021-12-08 - New Mervis IDE & OS v2.4.1 released ==
 +
 +In Mervis IDE v2.4.1 (**125493**),​ it is now possible for PLCs to define event-type tasks that run a specific program only if the corresponding value is set or the value of a two-state control variable has changed.
 +
 +Additionally,​ the option of advanced local website (HMI) customization has been added. This new functionality will help you create a product with your own branding. ​
 +
 +== 2021-05-20 - New Mervis IDE & OS v2.4.0 released ==
 +
 +In Mervis OS **v2.4.0.10**,​ support was added for Neuron S103-RPi4 and Unipi 1.1 controllers with RPi4 from the new series. These are controllers with a MAC address starting with **e4**:​**5f**:​xx:​xx:​xx:​xx.
 +
 +Emailing has been fixed for Mervis IDE v2.4.0 (**117845**). It is now possible to send emails using both SSL (port 465) and nonSSL (port 25) SMTP connections. ​
  
 == 2021-05-10 - New Mervis IDE v2.4.0 released ==  == 2021-05-10 - New Mervis IDE v2.4.0 released == 
-The database settings for Mervis SCADA have changed in the current version of Mervis IDE. In IDE version ​v2.3.0, the data for connection to the database were entered into the SCADA terminal, ​now they are entered under individual PLCs in the terminal. Read more in the manual [[en:​sw:​01-mervis:​mervis-scada-project-hidden#​creating_a_scada_terminal|Creating a Mervis SCADA project]]. +In the current version of the Mervis IDE v2.4.0 (**116580**)it is necessary to re-fill in the data for the Mervis DB in the SCADA terminal, ​if you use it. Read more in the manual [[en:​sw:​01-mervis:​mervis-scada-project-hidden|Creating a Mervis SCADA project]]. 
-Furthermore,​ it is possible ​to set the period of storing variables in the internal memory, which enabled a significant increase in storage life. New registers are used to monitor the state of the storagetheir description can be found in the [[en:​sw:​02-apis:​02-modbus-tcp?​tns#​storage_life_status|Modbus TCP article]]. + 
-Unfortunately,​ it is not possible to send e-mails in the current version of the IDE, a fix is being worked on.+The advantage of this version ​is the ability ​to set the period of storing variables in the internal memory. This enabled a significant increase in storage life, see the [[en:​sw:​02-apis:​02-modbus-tcp?​tns#​storage_life_status|article on Modbus TCP]]. ​for more information. 
 + 
 +Unfortunately,​ it is not possible to send e-mails in the current version of the IDE, a fix is being worked on. 
  
 == 2021-01-25 - Hardware section changed to Products ==  == 2021-01-25 - Hardware section changed to Products ==