en:hw:007-patron:service-mode [2021/03/11 11:31]
avsetula
en:hw:007-patron:service-mode [2021/03/16 12:16]
avsetula
Line 12: Line 12:
  
 ===== Startup in a service mode ===== ===== Startup in a service mode =====
-The service mode is accessed using the **SERVICE** button located ​above the red LED on the Unipi Gate device front plate. As the device'​s Ethernet ports work in bridge mode (br0 = ETH0 + ETH1) when the device ​is in the service mode, the ports should never be connected into the same network. The mode is physically ​indicated by the PWR diode continously emitting with the remaining LEDs blinking ([[en:​hw:​025-gate:​led-indication#​pwr_is_on_the_rest_is_blinking_600ms|demonstration here]] / [[en:​hw:​025-gate:​led-indication#​service_mode|startup simulator here]])+The **SERVICE** button, usually ​located ​next to USB labels, ​is important for accessing ​the service mode. The mode is indicated by the slow blinking of all LEDs both in the upper and lower LED row in section 1
    
-{{page>​en:​hw:​025-gate:​service-web-interface-hidden}}+{{page>​en:​hw:​007-patron:​service-web-interface-hidden}}
  
-As the next step for both cases, enter the device'​s IP address into your web browser'​s address bar. Upon confirmation,​ you will be connected to the Unipi Gate service interface.+As the next step for both cases, enter the device'​s IP address into your web browser'​s address bar. Upon confirmation,​ you will be connected to the Unipi Patron ​service interface.
  
 ===== Description of the service web interface ===== ===== Description of the service web interface =====
Line 27: Line 27:
 ---- ----
  
-<​html><​span class="​kbBlueText">​Under the ribbon are the following dialogue windows:</​span></​html> ​FIXME - +<​html><​span class="​kbBlueText">​Under the ribbon are the following dialogue windows:</​span></​html>​
   - **Settings** -> contains four buttons, all of them useable only in the regular mode::   - **Settings** -> contains four buttons, all of them useable only in the regular mode::
     * Set 192.168.200.200 on eth0 -> sets the ethernet interface to fixed 192.168.200.200 IP address     * Set 192.168.200.200 on eth0 -> sets the ethernet interface to fixed 192.168.200.200 IP address
Line 38: Line 38:
   - **Messages** -> displays a list of performed operations   - **Messages** -> displays a list of performed operations
 \\ \\
-<WRAP center round info 80%> ​FIXME +<WRAP center round info 80%> 
-Dialogové okno **Settings** ​může obsahovat ještě ​další tlačítka, pokud je na jednotce SW Mervis. +If Mervis is used, the **Settings** ​dialogue window can contain ​additional buttons
-  * Clear Mervis -> odstraní nahraný projekt, konfiguraci i webový obsah +  * Enable Mervis -> launches ​Mervis RT on the device 
-  * Enable Mervis -> spustí ​Mervis RT na zařízení +  * Disable Mervis -> stops Mervis RT on the device
-  * Disable Mervis -> zastaví ​Mervis RT na zařízení ​+
 </​WRAP>​ </​WRAP>​
 +\\
  
 {{ :​en:​hw:​patron_service_mode.png?​direct |}} {{ :​en:​hw:​patron_service_mode.png?​direct |}}