====== Unipi Extensions ====== | ====== Unipi Extensions ====== | ||
<WRAP center round tip 60%> | <WRAP center round tip 60%> | ||
- | Looking for a guide to connect the extensions to Neuron or Axon controllers? Please visit this [[https://kb.unipi.technology/en:sw:01-mervis:connecting-to-unipi-extension-hidden|detailed tutorial]]. | + | Looking for a guide to connect the extensions to Neuron or Axon controllers with Mervis? Please visit this [[https://kb.unipi.technology/en:sw:01-mervis:connecting-to-unipi-extension-hidden|detailed tutorial]]. |
</WRAP> | </WRAP> | ||
{{:en:hw:extensions_xs11_xs51-1.jpg|}} | {{:en:hw:extensions_xs11_xs51-1.jpg|}} | ||
Line 24: | Line 24: | ||
{{:en:hw:extension_use-case2.png|}} | {{:en:hw:extension_use-case2.png|}} | ||
+ | ==== Special functions ==== | ||
{{page>special-io-unipi-hidden}} | {{page>special-io-unipi-hidden}} | ||
- | |||
- | ==== Special functions ==== | ||
- | FIXME viz https://kb.unipi.technology/cs:hw:02-neuron#dalsi_funkce | ||
- | Along with standard inputs and outputs, the extension modules also feature other functions enhancing their performance. | ||
- | |||
- | == Direct Switch == | ||
- | This function connects a digital input with digital output or relay output. The function is independent on the master PLC and is suitable for time-critical applications (ie. lighting control). The function can be configured to one of three available modes: | ||
- | |||
- | * Copy: output is switched by an active input | ||
- | * Invert: output is switched by an inactive input | ||
- | * Toggle: output is switched by any change on the input | ||
- | |||
- | == Default settings == | ||
- | This function allows the user to store the default configuration of the module into its internal memory. If the module is rebooted, the default configuration is loaded automatically. | ||
- | |||
- | == Master Watchdog == | ||
- | The function monitors the communication between the module and the controller. If the communication is interrupted (eg. no response from the controller is detected within a defined time frame), the module automatically loads the default settings. This function keeps the module operational even in case of a controller failure or software issues. | ||
==== Configuration of communication parameters and addressing ==== | ==== Configuration of communication parameters and addressing ==== |