Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
en:hw:05-sensors:iaq [2020/12/16 13:53]
avsetula
en:hw:05-sensors:iaq [2021/09/06 11:23]
avsetula [Further info]
Line 5: Line 5:
  
 <WRAP center round info 90%> <WRAP center round info 90%>
-Product datasheets ​and technical documentation for indoor air quality sensors ​is available [[en:​files:​products:​05-sensors:​iaq|on this link]].+Product datasheetstechnical documentation ​and up-to-date firmware ​for indoor air quality sensors ​are available [[en:​files:​products:​05-sensors:​iaq|on this link]].
 </​WRAP>​ </​WRAP>​
 ==== Complete overview of individual variants: ==== ==== Complete overview of individual variants: ====
Line 36: Line 36:
  
 <​html><​span class="​kbBlueText">​Possible applications:</​span></​html>​ <​html><​span class="​kbBlueText">​Possible applications:</​span></​html>​
-  * when used with Unipi PLCs: an element of **MaR systems** using the **Modbus RTU/TCP** protocol+  * when used with Unipi units: an element of **MaR systems** using the **Modbus RTU/TCP** protocol
   * usage within a third-party system through RS485 or Wi-Fi interface using a suitable communication protocol   * usage within a third-party system through RS485 or Wi-Fi interface using a suitable communication protocol
   * individual use - communication through Wi-Fi with the option of web server access   * individual use - communication through Wi-Fi with the option of web server access
Line 50: Line 50:
 <​html><​span class="​kbBlueText">​Examples of use:</​span></​html>​ <​html><​span class="​kbBlueText">​Examples of use:</​span></​html>​
   * measuring temperature and relative air humidity to provide data for HVAC regulation   * measuring temperature and relative air humidity to provide data for HVAC regulation
-  * using internal air quality data (enhanced by CO<​sub>​2</​sub>​ concentration measurements) for regulation of ventilation and air recovery+  * using internal air quality data (enhanced by CO<​sub>​2</​sub>​ concentration measurements) for the regulation of ventilation and air recovery
   * controlling indoor artificial lights according to ambient light levels   * controlling indoor artificial lights according to ambient light levels
  
 <​html><​span class="​kbBlueText">​Possible applications:</​span></​html>​ <​html><​span class="​kbBlueText">​Possible applications:</​span></​html>​
-  * when used with Unipi PLCs: an element of **MaR systems** using the **Modbus RTU/TCP** protocol+  * when used with Unipi units: an element of **MaR systems** using the **Modbus RTU/TCP** protocol
   * usage within a third-party system through RS485 or Wi-Fi interface using a suitable communication protocol   * usage within a third-party system through RS485 or Wi-Fi interface using a suitable communication protocol
   * individual use - communication through Wi-Fi with the option of web server access   * individual use - communication through Wi-Fi with the option of web server access
Line 73: Line 73:
  
 <​html><​span class="​kbBlueText">​Possible applications:</​span></​html>​ <​html><​span class="​kbBlueText">​Possible applications:</​span></​html>​
-  * when used with Unipi PLCs: an element of **MaR systems** using the **Modbus RTU/TCP** protocol+  * when used with Unipi units: an element of **MaR systems** using the **Modbus RTU/TCP** protocol
   * usage within a third-party system through RS485 or Wi-Fi interface using a suitable communication protocol   * usage within a third-party system through RS485 or Wi-Fi interface using a suitable communication protocol
   * individual use - communication through Wi-Fi with the option of web server access   * individual use - communication through Wi-Fi with the option of web server access
Line 92: Line 92:
  
 <​html><​span class="​kbBlueText">​Possible applications:</​span></​html>​ <​html><​span class="​kbBlueText">​Possible applications:</​span></​html>​
-  * when used with Unipi PLCs: an element of **MaR systems** using the **Modbus RTU/TCP** protocol+  * when used with Unipi units: an element of **MaR systems** using the **Modbus RTU/TCP** protocol
   * usage within a third-party system through RS485 or Wi-Fi interface using a suitable communication protocol   * usage within a third-party system through RS485 or Wi-Fi interface using a suitable communication protocol
   * individual use - communication through Wi-Fi with the option of web server access   * individual use - communication through Wi-Fi with the option of web server access
Line 99: Line 99:
 {{ :​files:​img_breakline.png?​nolink |}} {{ :​files:​img_breakline.png?​nolink |}}
 ===== LoRa frame decoder code ===== ===== LoRa frame decoder code =====
-Example of binary payload decoder. Function names are in accordance with The Things Network.+Example of binary payload decoder. Function names are in accordance with ''​The Things Network''​. 
 <​code>​ <​code>​
 function getBit(number,​ bitPosition) { function getBit(number,​ bitPosition) {
Line 132: Line 133:
  
 ===== Further info ===== ===== Further info =====
-  * [[en:​files:​products:​05-sensors| Documentation and related files for download]] + 
-  * [[https://www.unipi.technology/​indoor-air-quality-sensor-p299?​categoryId=43| Buy at Unipi]]+<​tile>​ 
 +en:​files:​products:​05-sensors:iaq            ​| Documentation and firmaware ​for download  ​| :en:files:unipi-kb-icon-os.png         | 
 +| en:hw:05-sensors:iaq-eshop-redirect-hidden  ​| Buy at Unipi e-shop ​                      | :​files:​unipi-kb-icon-shopping-cart-outline.png ​ | 