-Sorry, this article is under construction+Unipi sensors are divided by the technology used and their application (indoor or outdoor use).  
 + 
 +<​tile>​ 
 +| en:​hw:​05-sensors:​1-wire ​ | 1-Wire ​ | :​files:​unipi-kb-icon-1-wire-long.png ​           |  
 +| en:​hw:​05-sensors:​analog ​ | Analog ​ | :​files:​unipi-kb-icon-sensors-sensor-analog.png ​ | 
 +| en:​hw:​05-sensors:​iaq ​    | IAQ     | :​files:​unipi-kb-icon-sensors.png ​               | 
 +</​tile>​ 
 +===== 1-Wire ===== 
 +If you need only temperature or humidity sensors1-Wire devices are an ideal choice. You can choose from indoor, outdoor, sump, water-proof or other specialized sensors. [[https://​www.unipi.technology/​1-wire-c3|Our product listing]] includes temperature sensors designed for measurements in boiler rooms, HVAC installations etc. We also offer indoor **temperature** and **temperature/​humidity** sensors, each having two variants differing in their design.  
 + 
 +These sensors are described in detail in [[en:​hw:​05-sensors:​1-wire|this article ​focused on Unipi 1-Wire devices]]. More info about the 1-Wire bus and **sensor connection** ​is available [[en:​automation:​02-glossary:​1wire-hidden|in this 1-Wire article]]. 
 + 
 +===== Analog sensors ===== 
 +If you require very precise temperature readings, you can achieve so with analog sensors. This type of sensors is available in outdoor, sump, water-proof or otherwise specialised variants. [[https://​www.unipi.technology/​resistance-sensors-c49|On our e-shop]], you can find mainly temperature sensors designed for measurements in boiler rooms, air conditioning systems etc. 
 + 
 +For more detailed description of these sensors, visit the article about [[en:​hw:​05-sensors:​analog|analog sensors available on our e-shop]]. For more info about the 1-Wire bus and **sensor connection**,​ please visit [[en:​automation:​02-glossary:​1wire-hidden|this article about 1-Wire]]. 
 + 
 +===== IAQ - Interior Air Quality ===== 
 +If you are interested in a **complex solution**, we recommend using our brand-new on-wall IAQ sensors designed for general **air quality monitoring** in rooms the sensor is installed in.  
 + 
 +<​html><​span class="​kbBlueText">​A list of quantities measured using the sensors:</​span></​html>​ 
 +  * air temperature 
 +  * air humidity 
 +  * VOC (volatile organic compound) concentration - air quality index 
 +  * barometric pressure 
 +  * ambient light 
 +  * CO<​sub>​2</​sub>​ concentration* 
 + 
 +The device is available **in four variants**. All variants feature sensors of temperature,​ humidity, pressure, ambient light and VOC. The first variant is equipped only with those basic sensors, the second adds **CO<​sub>​2</​sub>​ sensor**. The other two variants share the same functionality but are also provided with the **LoRaWAN** communication interface.  
 + 
 +Each variant features at least two communication interfaces, the first being **RS485** and the second represented by well-known **Wi-Fi**. RS485 interface utilizes the **Modbus RTU** protocol, while the Wi-Fi support multiple protocols including **Modbus TCP, MQTT, and HTTP/REST** and a web interface, serving also for management and configuration of the device.  
 + 
 +Additional info is available in the following article: [[en:​hw:​05-sensors:​iaq|]]