Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| en:hw:connection-of-di-hidden [2021/04/28 08:39] – avsetula | en:hw:connection-of-di-hidden [2025/04/03 19:21] (current) – avsetula | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | Digital inputs serve for an indication | + | /* |
| + | INCLUDED IN: | ||
| + | - en: | ||
| + | */ | ||
| - | <WRAP center round info 95%> | + | Digital inputs serve for an indication of TRUE/FALSE logic states and can be also used as [[# |
| - | **TRUE logic state** (switched on) on input is indicated by LED with the corresponding marking matching the input label. | + | |
| + | < | ||
| + | {{ : | ||
| + | <WRAP half column 13%> | ||
| + | {{: | ||
| + | </ | ||
| + | <WRAP half column 83%> | ||
| + | **Log. 1** (switched on) on input is indicated by LED with the corresponding marking matching the input label. | ||
| + | </ | ||
| </ | </ | ||
| - | The software detects TRUE state if the input voltage between the given DIx and DIGND terminals is in range of 7-35V DC. If the voltage decreases below 3 VDC, the FALSE state is indicated. The voltage between 3-7 VDC is detected as a non-defined state. | + | The software detects TRUE state if the input voltage between the given DIx and DIGND terminals is in range of 7-35 V⎓. If the voltage decreases below 3 V⎓, the FALSE state is indicated. The voltage between 3-7 V⎓ is detected as a non-defined state. |
| ====== Connection ====== | ====== Connection ====== | ||
| - | Each connector with digital inputs features a common **DIGND** terminal for connection of DC power source negative pole. The positive pole of the power supply is to be connected to the **DIx**, or **DIy.x** terminal through the connected external device. See the following image for illustration: | + | Each connector with digital inputs features a common **DIGND** terminal for connection of DC power source negative pole. The positive pole of the power supply is to be connected to the **DIx** or **DIy.x** terminal through the connected external device. See the following image for illustration: |
| {{ : | {{ : | ||
| - | <WRAP center round info 95%> | + | < |
| - | **Note:** \\ | + | {{ : |
| - | For connection of external devices to digital inputs, we recommend using a different (separate) power supply from the one used to power the device (PLC / Extension) in order to retain galvanic isolation. Each digital input group also feature a DIGND terminal added specifically for connection of the separate power supply negative pole. | + | <WRAP half column 13%> |
| + | {{: | ||
| + | </ | ||
| + | <WRAP half column 83%> | ||
| + | **Please note:** \\ | ||
| + | For connection of external devices to digital inputs, we recommend using a different (separate) power supply from the one used to power the device (unit/Extension) in order to retain galvanic isolation. Each digital input group also feature a DIGND terminal added specifically for connection of the separate power supply negative pole. | ||
| + | </ | ||
| </ | </ | ||