 ====== Mervis certification ====== ====== Mervis certification ======
  
-Certification programme is intended for those interested in [[https://​www.unipi.technology/​become-partner|UniPi partnership programme]]. The certification is contingent upon completing a certification task in the form of a practical automation solution using the UniPi certification kit.+Certification programme is intended for those interested in [[https://​www.unipi.technology/​become-partner|Unipi partnership programme]]. The certification is contingent upon completing a certification task in the form of a practical automation solution using the Unipi certification kit.
  
 <WRAP center round info 60%> <WRAP center round info 60%>
Line 11: Line 11:
    
 Room heating control consists of:  Room heating control consists of: 
-  * controlling ​a heater using RE2 relay +  * Controlling ​a heater using RE2 relay 
-  * temperature ​measurement using the PT1000 resistance thermometer +  * Temperature ​measurement using the PT1000 resistance thermometer 
-  * using a programmable week scheduler for setting the required temperature +  * Using a programmable week scheduler for setting the required temperature 
-  * an option to manually adjust the temperature by +-3°C using the potentiometer +  * An option to manually adjust the temperature by +-3°C using the potentiometer 
-  * displaying ​a current and adjusted required temperature through a web HMI +  * Displaying ​a current and adjusted required temperature through a web HMI 
-  * displaying ​a current heater status through a web HMI+  * Displaying ​a current heater status through a web HMI
    
 Lighting control consists of:  Lighting control consists of: 
-  * control ​of a single lighting circuit through a relay (RE1) +  * Control ​of a single lighting circuit through a relay (RE1) 
-  * physical ​lighting control using the red button +  * Physical ​lighting control using the red button 
-  * lighting ​control using a web HMI+  * Lighting ​control using a web HMI
  
 Recommended methods Recommended methods
-  * implement ​the hysteresis control ("​On-Off Control - Heating (B31)" block) +  * Implement ​the hysteresis control ("​On-Off Control - Heating (B31)" block) 
-  * use "Real Scheduler (T18)" block for creating the timetable +  * Use "Real Scheduler (T18)" block for creating the timetable 
-  * transform ​the potentiometer output value to 3-/+3 using a linear transformation +  * Transform ​the potentiometer output value to 3-/+3 using a linear transformation 
-  * connect ​the lighting control button to the relay using the Direct Switch Toggle function +  * Connect ​the lighting control button to the relay using the Direct Switch Toggle function 
-  * for simultaneous control of the Direct Switch output, use the library provided +  * For simultaneous control of the Direct Switch output, use the library provided 
-  * encapsulate ​the whole solution into a single function block for better convenience+  * Encapsulate ​the whole solution into a single function block for better convenience
    
 Assembly of the certification kit Assembly of the certification kit
-  * fasten ​DIN rail holders to both the Axon S105 controller and the xS11 extension module using the provided screws +  * Fasten ​DIN rail holders to both the Axon S105 controller and the xS11 extension module using the provided screws 
-  * mount the controllers,​ terminals and relays to the DIN rail according to {{:​cs:​sw:​01-mervis:​schema_xs11.pdf |this scheme}} +  * Mount the controllers,​ terminals and relays to the DIN rail according to {{:​cs:​sw:​01-mervis:​schema_xs11.pdf |this scheme}} 
-  * interconnect ​blue terminals with the 2-way jumper +  * Interconnect ​blue terminals with the 2-way jumper 
-  * interconnect ​red and grey terminals with the 3-way jumper +  * Interconnect ​red and grey terminals with the 3-way jumper 
-  * insert ​the resistance housing into the grey terminal +  * Insert ​the resistance housing into the grey terminal 
-  * connect ​all cables and conductors according to {{:​cs:​sw:​01-mervis:​schema_xs11.pdf |the scheme}} +  * Connect ​all cables and conductors according to {{:​cs:​sw:​01-mervis:​schema_xs11.pdf |the scheme}} 
-  * prior to connecting the power source, check the correct voltage polarity+  * Before ​connecting the power source, check the correct voltage polarity