-Certification ​programme ​is intended for those interested in [[https://​www.unipi.technology/​become-partner|Unipi partnership programme]]. The certification is contingent upon completing a certification task in the form of a practical automation solution using the Unipi certification kit.+Certification ​program ​is intended for those interested in [[https://​www.unipi.technology/​become-partner|Unipi partnership programme]]. The certification is contingent upon completing a certification task in the form of a practical automation solution using the Unipi certification kit.
  
 <WRAP center round info 60%> <WRAP center round info 60%>
Line 11: Line 11:
    
 <​html><​span class="​kbBlueText">​Assembly of the certification kit:</​span></​html>​ <​html><​span class="​kbBlueText">​Assembly of the certification kit:</​span></​html>​
-  * Fasten DIN rail holders to both the Neuron S103 controller ​and the xS11 extension module using the provided screws +  * Fasten DIN rail holders to both the Patron S107 unit and the xS11 extension module using the provided screws 
-  * Mount the controllers, terminals and relays to the DIN rail according to {{ :​en:​sw:​01-mervis:​schema_s103_xs11_.pdf |this scheme}}+  * Mount the units, terminals and relays to the DIN rail according to {{ :​en:​sw:​01-mervis:​schema_s103_xs11_.pdf |this scheme}}
   * Interconnect blue terminals with the 2-way jumper   * Interconnect blue terminals with the 2-way jumper
   * Interconnect red and grey terminals with the 3-way jumper   * Interconnect red and grey terminals with the 3-way jumper
Line 37: Line 37:
   * Transform the potentiometer output value to 3-/+3 using a linear transformation   * Transform the potentiometer output value to 3-/+3 using a linear transformation
   * Connect the lighting control button to the relay using the Direct Switch Toggle function   * Connect the lighting control button to the relay using the Direct Switch Toggle function
-  * For simultaneous control of the Direct Switch output, use the library provided+  * For simultaneous control of the Direct Switch output, use the Force Output register