Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:sw:01-mervis:creating-external-hmi-hidden [2020/05/14 12:47]
avsetula
en:sw:01-mervis:creating-external-hmi-hidden [2021/08/05 15:07] (current)
avsetula
Line 2: Line 2:
 {{page>​creating-hmi-intro-hidden}} {{page>​creating-hmi-intro-hidden}}
  
-==== Prerequisites ​====  +<WRAP center round box> 
-  * One or more [[https://​www.unipi.technology/​axon-c20|UniPi]] PLCs with [[en:​files:​software:​os-images:​00-start|the Mervis OS]] +<​html><​span class="​kbBlue-H4alt">​Prerequisites:</​span></​html>​ 
-  * [[https://​www.unipi.technology/​accessories-c4|24V DC power supply]]+  * One or more [[https://​www.unipi.technology/​axon-c20|Unipi]] PLCs with [[en:​files:​software:​os-images:​00-start|the Mervis OS]] 
 +  * [[https://​www.unipi.technology/​accessories-c4|24 V⎓ power supply]]
   * Local network connection (any suitable switch or router)   * Local network connection (any suitable switch or router)
 +</​WRAP>​
  
 ===== Creating a terminal for external HMI ===== ===== Creating a terminal for external HMI =====
Line 47: Line 49:
 </​figure></​html>​ </​figure></​html>​
  
-Right-click on the "​terminalChannel"​ channel and select **Add Device**. ​+Right-click on the "**terminalChannel**" channel and select **Assign ​Device**. ​
  
 <​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​en:​sw:​01-mervis:​05_creating-external-hmi-en.png)">​ <​html><​figure ondblclick="​redirectImg(this)"​ class="​zoom"​ onclick="​zoom(event)"​ style="​background-image:​ url(https://​kb.unipi.technology/​_media/​en:​sw:​01-mervis:​05_creating-external-hmi-en.png)">​
Line 74: Line 76:
  
 <​html><​span class="​kbBlueText">​SSCP Parameters:</​span></​html>​ <​html><​span class="​kbBlueText">​SSCP Parameters:</​span></​html>​
-  * **Endpoint:** Custom+  * **EndPoint:** Custom
   * **Device Address:** //select according to the PLC's address//   * **Device Address:** //select according to the PLC's address//
   * **User:** //name of the PLC user - **Full Control** will be enough//   * **User:** //name of the PLC user - **Full Control** will be enough//
Line 81: Line 83:
  
 <​html><​span class="​kbBlueText">​TCP Parameters:</​span></​html>​ <​html><​span class="​kbBlueText">​TCP Parameters:</​span></​html>​
-  * **Device ​Address:** //enter an IP address, PLC domain or proxy connection address// - '​proxy.unipi.technology''​+  * **Device ​Hostname:** //enter an IP address, PLC domain or proxy connection address// - '​proxy.unipi.technology''​
   * **Device Port:** 12346 (proxy: 12348)   * **Device Port:** 12346 (proxy: 12348)