 ====== Uploading a RunTime configuration ====== ====== Uploading a RunTime configuration ======
 +/*
 <WRAP group> <WRAP group>
 <WRAP half column 81%> <WRAP half column 81%>
 +*/
 Each time you wish to upload RT configuration changes, make sure, that you downloaded the PLC config beforehand. We also recommend to double-check settings of your network card and make sure it is compatible with the required configuration (mainly if the DHCP client is enabled). After these checks, set the configuration.  Each time you wish to upload RT configuration changes, make sure, that you downloaded the PLC config beforehand. We also recommend to double-check settings of your network card and make sure it is compatible with the required configuration (mainly if the DHCP client is enabled). After these checks, set the configuration. 
 +/*
 </WRAP> </WRAP>
 <WRAP half column 15%> <WRAP half column 15%>
Line 18: Line 21:
 </WRAP> </WRAP>
 </WRAP> </WRAP>
 +*/
  
 After finishing the configuration, unroll the PLC, right-click on //Configuration//, select <html><span class="avBlueText">Upload configuration</span></html> After finishing the configuration, unroll the PLC, right-click on //Configuration//, select <html><span class="avBlueText">Upload configuration</span></html>
Line 33: Line 37:
 For uploading configurations or projects, the fast and reliable TCP is used. However, this method also requires you to know connection parameters, such as IP address. Through the TCP it is possible to communicate also via a proxy server.  For uploading configurations or projects, the fast and reliable TCP is used. However, this method also requires you to know connection parameters, such as IP address. Through the TCP it is possible to communicate also via a proxy server. 
  
-<WRAP center round important 80%> +<WRAP group center round box 95%> 
-**Caution:** if you are unable to upload configuration, upload a new project etc. after a password change, the most likely cause is you uploaded a wrong password by error. If you can't remember the correct password, you can reflash the PLC's operating system as a last-resort solution. See the corresponding guides for [[en:hw:007-patron:image|Unipi Patron]], [[en:hw:01-axon:image|Unipi Axon]] and [[en:sw:01-mervis:running-on-neuron-hidden|Unipi Neuron/Unipi 1.1]].+{{ :files:img_warning-line_b.png?nolink |}} 
 +<WRAP half column 13%> 
 +{{ :en:hw:09_safety-instructions_pseudo-ISO-7010-attention.png?nolink |(!)}} 
 +</WRAP> 
 +<WRAP half column 83%> 
 +**Caution:** \\ 
 +if you are unable to upload configuration, upload a new project etc. after a password change, the most likely cause is you uploaded a wrong password by error. If you can't remember the correct password, you can reflash the PLC's operating system as a last-resort solution. See the corresponding guides for [[en:hw:007-patron:image|Unipi Patron]], [[en:hw:01-axon:image|Unipi Axon]] and [[en:sw:01-mervis:running-on-neuron-hidden|Unipi Neuron/Unipi 1.1]]. 
 +</WRAP>
 </WRAP> </WRAP>
  
Line 227: Line 238:
 </WRAP> </WRAP>
  
-<WRAP center round info 90%>+<WRAP group center round box 95%> 
 +{{ :files:img_warning-line_b.png?nolink |}} 
 +<WRAP half column 13%> 
 +{{ :en:hw:08_safety-instructions_pseudo-ISO-7010-info.png?nolink |(!)}} 
 +</WRAP> 
 +<WRAP half column 83%> 
 +**Note:** \\
 These settings are common for all interfaces. These settings are common for all interfaces.
 +</WRAP>
 </WRAP> </WRAP>
  
Line 281: Line 299:
 </WRAP> </WRAP>
  
-You can add network interfaces to the Bridge by right clicking it → //Přiřadit síťové rozhraní// → desired interface:+You can add network interfaces to the Bridge by right clicking it → //Add Network Interface Reference// → desired interface:
 {{ :en:sw:01-mervis:updating-a-runtime-configuration:network-bridge-add-path.png?direct |Adding an interface to the bridge}} {{ :en:sw:01-mervis:updating-a-runtime-configuration:network-bridge-add-path.png?direct |Adding an interface to the bridge}}
  
-<WRAP center round important 80%>+<WRAP group center round box 95%> 
 +{{ :files:img_warning-line_b.png?nolink |}} 
 +<WRAP half column 13%> 
 +{{ :en:hw:09_safety-instructions_pseudo-ISO-7010-attention.png?nolink |(!)}} 
 +</WRAP> 
 +<WRAP half column 83%> 
 +**Attention:** \\
 After you add a network interface to the bridge, you have to set its parameter //IP Configuration// to //none//. After you add a network interface to the bridge, you have to set its parameter //IP Configuration// to //none//.