==== Mervis DB ==== | ==== Mervis DB ==== | ||
- | URL for the PLC to save data into a database (can be set in PLC properties -> Mervis DB Parameters | + | URL for the unit to save data into a database (can be set in PLC properties -> Mervis DB Parameters |
* Mervis IDE 2.3.0 and newer: <code>https://db.unipi.technology/plc/save</code> | * Mervis IDE 2.3.0 and newer: <code>https://db.unipi.technology/plc/save</code> | ||
* Mervis IDE 2.2.0 and older: <code>http://db.unipi.technology/plc/save</code> | * Mervis IDE 2.2.0 and older: <code>http://db.unipi.technology/plc/save</code> | ||
- | Link to a user interface: https://db.unipi.technology/viewer | + | Link to a user interface: https://db.unipi.technology/viewer |
<WRAP center round tip 60%> | <WRAP center round tip 60%> | ||
Line 13: | Line 13: | ||
API access to database (ie. for Mervis SCADA): <code>https://db.unipi.technology/dbaccess</code> | API access to database (ie. for Mervis SCADA): <code>https://db.unipi.technology/dbaccess</code> | ||
+ | |||
+ | or: <code>http://db.unipi.technology/dbaccess</code> | ||
==== Mervis Proxy ==== | ==== Mervis Proxy ==== | ||
- | URL for connecting the PLC to the Mervis Proxy (PLC Properties -> Proxy Parameters -> URL): | + | URL for connecting the unit to the Mervis Proxy (PLC Properties -> Proxy Parameters -> URL): |
* Mervis IDE 2.3.0 and newer: <code>https://proxy.unipi.technology:6678</code> | * Mervis IDE 2.3.0 and newer: <code>https://proxy.unipi.technology:6678</code> | ||
* Mervis IDE 2.2.0 and older: <code>http://proxy.unipi.technology:6677</code> | * Mervis IDE 2.2.0 and older: <code>http://proxy.unipi.technology:6677</code> | ||
- | URI for connecting Mervis IDE or Mervis SCADA to PLC using Mervis Proxy (PLC Properties -> Connection Parameters -> URI): | + | URL for connecting Mervis IDE or Mervis SCADA to unit using Mervis Proxy (PLC Properties -> Connection Parameters -> URI): |
* Mervis IDE 2.3.0 and newer: <code>tcps://proxy.unipi.technology:12349</code> | * Mervis IDE 2.3.0 and newer: <code>tcps://proxy.unipi.technology:12349</code> | ||
* Mervis IDE 2.2.0 and older: <code>tcp://proxy.unipi.technology:12348</code> | * Mervis IDE 2.2.0 and older: <code>tcp://proxy.unipi.technology:12348</code> | ||
Line 26: | Line 28: | ||
Link for access to the Mervis SCADA interface can be found in the [[en:sw:01-mervis:05-mervis-scada|Mervis SCADA]] article. | Link for access to the Mervis SCADA interface can be found in the [[en:sw:01-mervis:05-mervis-scada|Mervis SCADA]] article. | ||
- | /* Přeložit - FIXME | + | All necessary info along with links for Mervis Proxy and Mervis DB to be inserted into the SCADA terminal and the attached unit is available in the [[en:sw:01-mervis:mervis-scada-project-hidden#creating_a_scada_terminal|Mervis SCADA tutorial]], Chapter 2.1 -> Creating a SCADA terminal. |
- | Všechny potřebné informace a odkazy Mervis Proxy a DB k vložení do terminálu SCADA a přiřazeného PLC naleznete v [[cs:sw:01-mervis:mervis-scada-project-hidden#vytvoreni_terminalu_scada|návodu pro Mervis SCADA]] v kapitole 2.1 -> Vytvoření terminálu SCADA. | + | |
- | */ | + | |
<WRAP center round tip 60%> | <WRAP center round tip 60%> | ||
You can access the interface only using the login and password generated in the Mervis SCADA management panel in the [[https://www.unipi.technology/|Unipi Technology]] web customer section. | You can access the interface only using the login and password generated in the Mervis SCADA management panel in the [[https://www.unipi.technology/|Unipi Technology]] web customer section. | ||