Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
en:sw:01-mervis [2018/07/17 08:36] mkudlacek |
en:sw:01-mervis [2022/08/22 11:00] avsetula |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ======%hide Mervis ====== | + | ~~NOTOC~~ |
+ | ======%hide Mervis ====== | ||
- | {{ :en:sw:mervis_color_without_padding.png?400 |}} | + | {{ :en:sw:mervis_color_without_padding.png?400&nolink |}} |
\\ | \\ | ||
- | Mervis is our primary, officially supported, full-fledged software platform for controlling UniPi controllers. It allows you to: | + | <html><span class="kbBlueText">Mervis is our primary, officially supported, a full-fledged software platform for controlling Unipi units. It allows you to:</span></html> |
- | * Create programs in accordance with the [[en:automation:02-glossary:08-iec61131-3|IEC 61131-3 standard]] | + | * Create programs in accordance with the [[en:automation:02-glossary:iec61131-3-hidden|IEC 61131-3 standard]] |
* Build a web-based HMIs (human-machine interfaces) | * Build a web-based HMIs (human-machine interfaces) | ||
- | * Set long-term saving of data into cloud or on-premises database | + | * Set long-term saving of data into the cloud or on-premises database |
- | * Control your whole automation setup with SCADA interface | + | * Control your whole automation solution with SCADA interface |
- | * Access your controllers over internet via proxy server | + | * Access your units over the internet via a proxy server |
{{gallery>:en:sw:01-mervis:?sw_mervis*&2000X2000&lightbox}} | {{gallery>:en:sw:01-mervis:?sw_mervis*&2000X2000&lightbox}} | ||
- | **Mervis platform includes:** | + | <html><span class="kbBlueText">Mervis platform includes:</span></html> |
- | * [[en:sw:01-mervis:01-mervis-ide|Mervis IDE]]: software for configuration, programming and debugging controllers | + | * [[en:sw:01-mervis:01-mervis-ide|Mervis IDE]]: the main software for configuration, programming&debugging and creating visualizations |
- | * [[en:sw:01-mervis:02-mervis-rt|Mervis RT]]: software running on the PLC, responsible for executing program prepared in Mervis IDE | + | * [[en:sw:01-mervis:02-mervis-rt|Mervis RT]]: software running on the unit, responsible for executing a program prepared in Mervis IDE |
- | * [[en:sw:01-mervis:03-mervis-db|Mervis DB]]: database for long-term saving of data from your automation setup | + | * [[en:sw:01-mervis:03-mervis-db|Mervis DB]]: database for long-term saving of data from your units |
- | * [[en:sw:01-mervis:04-mervis-proxy|Mervis Proxy]]: service for accessing PLCs over internet | + | * [[en:sw:01-mervis:04-mervis-proxy|Mervis Proxy]]: service for remote service access to the units over the internet |
- | * [[en:sw:01-mervis:05-mervis-scada|Mervis SCADA]]: visualisation tool for complete control over whole automation setup | + | * [[en:sw:01-mervis:05-mervis-scada|Mervis SCADA]]: supervizor control, visualisation and analytics tool for every project |
\\ | \\ | ||
- | **Supported communication protocols:** | + | <html><span class="kbBlueText">Supported communication protocols:</span></html> |
- | + | ||
- | |< 50% >| | + | |
- | ^ Protocol ^ Client ^ Server ^ | + | |
- | | Modbus TCP | Yes | Yes | | + | |
- | | Modbus RTU | Yes | Yes | | + | |
- | | BACnet | no | Yes (basic data types) | | + | |
- | | SSCP | Yes | Yes | | + | |
- | | M-Bus | Yes | No | | + | |
- | | IEC 62056-21 | Yes | No | | + | |
- | | AMiT DB-Net/IP | Yes | No | | + | |
+ | |< 80% >| | ||
+ | ^ Protocol ^ Client ^ Server ^ Ethernet ^ RS485/232 ^ | ||
+ | |<html>  </html> Modbus TCP/RTU | ☑ | ☑ | ☑ | ☑ | | ||
+ | |<html>  </html> BACnet IP | ☑ | ☑ | ☑ | | | ||
+ | |<html>  </html> SSCP | ☑ | ☑ | ☑ | | | ||
+ | |<html>  </html> SoftPLC Link | ☑ | | ☑ | | | ||
+ | |<html>  </html> AMiT DB-Net/IP | ☑ | | ☑ | | | ||
+ | |<html>  </html> M-Bus | ☑ | | | ☑ | | ||
+ | |<html>  </html> Jablotron 100 | ☑ | | | ☑ | | ||
+ | |<html>  </html> IEC 62056-21 | ☑ | | | ☑ | | ||
+ | |<html>  </html> Hitachi H-protocol | ☑ | | | ☑ | | ||
+ | |<html>  </html> SMA-net | ☑ | | | ☑ | | ||
+ | |<html>  </html> 1-Wire | ☑ | | | | | ||
\\ | \\ | ||
<WRAP center round info 80%> | <WRAP center round info 80%> | ||
- | Mervis is supported by all UniPi controllers. For Neuron and Axon, the license is included into the purchase of the controller. For UniPi 1.1, the license has to be [[https://www.unipi.technology/mervis-p56|purchased separately]]. | + | Mervis is supported by Unipi units from Patron and Neuron production line. Each Unipi Patron or Neuron controller is shipped with Mervis RT license and login credentials for Mervis DB and Mervis Proxy services included in the package. For Unipi 1.1 or Unipi Gate the license has to be [[https://www.unipi.technology/mervis-p56|purchased separately]]. |
</WRAP> | </WRAP> | ||
- | |||
- | ~~NOTOC~~ |