Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:sw:01-mervis [2020/05/21 12:02]
avsetula [Mervis]
en:sw:01-mervis [2023/04/24 07:32] (current)
avsetula
Line 5: Line 5:
 \\ \\
  
-<​html><​span class="​kbBlueText">​Mervis is our primary, officially supported, a full-fledged software platform for controlling Unipi controllers. It allows you to:</​span></​html>​+<​html><​span class="​kbBlueText">​Mervis is our primary, officially supported, a full-fledged software platform for controlling Unipi units. It allows you to:</​span></​html>​
  
   * Create programs in accordance with the [[en:​automation:​02-glossary:​iec61131-3-hidden|IEC 61131-3 standard]]   * Create programs in accordance with the [[en:​automation:​02-glossary:​iec61131-3-hidden|IEC 61131-3 standard]]
   * Build a web-based HMIs (human-machine interfaces)   * Build a web-based HMIs (human-machine interfaces)
   * Set long-term saving of data into the cloud or on-premises database   * Set long-term saving of data into the cloud or on-premises database
-  * Control your whole automation ​setup with SCADA interface +  * Control your whole automation ​solution ​with SCADA interface 
-  * Access your controllers ​over the internet via a proxy server+  * Access your units over the internet via a proxy server
  
 {{gallery>:​en:​sw:​01-mervis:?​sw_mervis*&​2000X2000&​lightbox}} {{gallery>:​en:​sw:​01-mervis:?​sw_mervis*&​2000X2000&​lightbox}}
Line 18: Line 18:
 <​html><​span class="​kbBlueText">​Mervis platform includes:</​span></​html>​ <​html><​span class="​kbBlueText">​Mervis platform includes:</​span></​html>​
   * [[en:​sw:​01-mervis:​01-mervis-ide|Mervis IDE]]: the main software for configuration,​ programming&​debugging and creating visualizations   * [[en:​sw:​01-mervis:​01-mervis-ide|Mervis IDE]]: the main software for configuration,​ programming&​debugging and creating visualizations
-  * [[en:​sw:​01-mervis:​02-mervis-rt|Mervis RT]]: software running on the PLC, responsible for executing program prepared in Mervis IDE +  * [[en:​sw:​01-mervis:​02-mervis-rt|Mervis RT]]: software running on the unit, responsible for executing ​program prepared in Mervis IDE 
-  * [[en:​sw:​01-mervis:​03-mervis-db|Mervis DB]]: database for long-term saving of data from your PLCs +  * [[en:​sw:​01-mervis:​03-mervis-db|Mervis DB]]: database for long-term saving of data from your units 
-  * [[en:​sw:​01-mervis:​04-mervis-proxy|Mervis Proxy]]: service for remote service access to the PLCs over internet+  * [[en:​sw:​01-mervis:​04-mervis-proxy|Mervis Proxy]]: service for remote service access to the units over the internet
   * [[en:​sw:​01-mervis:​05-mervis-scada|Mervis SCADA]]: supervizor control, visualisation and analytics tool for every project   * [[en:​sw:​01-mervis:​05-mervis-scada|Mervis SCADA]]: supervizor control, visualisation and analytics tool for every project
  
 \\ \\
  
-<​html><​span class="​kbBlueText">​Supported communication protocols:</​span></​html>​+<​html><​span class="​kbBlueText" id="​protocols">​Supported communication protocols:</​span></​html>​
  
 |< 80%                                                  >| |< 80%                                                  >|
 ^ Protocol ​          ​^ ​ Client ​ ^  Server ​ ^  Ethernet ​ ^  RS485/​232 ​ ^ ^ Protocol ​          ​^ ​ Client ​ ^  Server ​ ^  Ethernet ​ ^  RS485/​232 ​ ^
 |<​html>&​nbsp&​nbsp</​html>​ Modbus TCP/​RTU ​     |  ☑  |  ☑  |  ☑  |  ☑  | |<​html>&​nbsp&​nbsp</​html>​ Modbus TCP/​RTU ​     |  ☑  |  ☑  |  ☑  |  ☑  |
-|<​html>&​nbsp&​nbsp</​html>​ BACnet ​             |  ☑  |  ☑  |  ☑  |     |+|<​html>&​nbsp&​nbsp</​html>​ BACnet ​IP           |  ☑  |  ☑  |  ☑  |     |
 |<​html>&​nbsp&​nbsp</​html>​ SSCP                |  ☑  |  ☑  |  ☑  |     | |<​html>&​nbsp&​nbsp</​html>​ SSCP                |  ☑  |  ☑  |  ☑  |     |
 |<​html>&​nbsp&​nbsp</​html>​ SoftPLC Link        |  ☑  |     ​| ​ ☑  |     | |<​html>&​nbsp&​nbsp</​html>​ SoftPLC Link        |  ☑  |     ​| ​ ☑  |     |
Line 36: Line 36:
 |<​html>&​nbsp&​nbsp</​html>​ M-Bus               ​| ​ ☑  |     ​| ​    ​| ​ ☑  | |<​html>&​nbsp&​nbsp</​html>​ M-Bus               ​| ​ ☑  |     ​| ​    ​| ​ ☑  |
 |<​html>&​nbsp&​nbsp</​html>​ Jablotron 100       ​| ​ ☑  |     ​| ​    ​| ​ ☑  | |<​html>&​nbsp&​nbsp</​html>​ Jablotron 100       ​| ​ ☑  |     ​| ​    ​| ​ ☑  |
-|<​html>&​nbsp&​nbsp</​html>​ IEC 62056-21 ​       |  ☑  |     ​| ​    ​| ​ ☑  | +|<​html>&​nbsp&​nbsp</​html>​ IEC 62056-21 ​       |  ☑  |     ​| ​    ​| ​ ☑  | /* 
-|<​html>&​nbsp&​nbsp</​html>​ Hitachi H-protocol ​ |  ☑  |     ​| ​    ​| ​ ☑  |+|<​html>&​nbsp&​nbsp</​html>​ Hitachi H-protocol ​ |  ☑  |     ​| ​    ​| ​ ☑  | */
 |<​html>&​nbsp&​nbsp</​html>​ SMA-net ​            ​| ​ ☑  |     ​| ​    ​| ​ ☑  | |<​html>&​nbsp&​nbsp</​html>​ SMA-net ​            ​| ​ ☑  |     ​| ​    ​| ​ ☑  |
 |<​html>&​nbsp&​nbsp</​html>​ 1-Wire ​             |  ☑  |     ​| ​    ​| ​    | |<​html>&​nbsp&​nbsp</​html>​ 1-Wire ​             |  ☑  |     ​| ​    ​| ​    |
Line 43: Line 43:
  
 <WRAP center round info 80%> <WRAP center round info 80%>
-Mervis is supported by all Unipi controllers. Each Unipi Axon or Neuron controller is shipped with Mervis RT license and login credentials for Mervis DB and Mervis Proxy services included in the package. For UniPi 1.1the license has to be [[https://​www.unipi.technology/​mervis-p56|purchased separately]].+Mervis is supported by Unipi units from Patron and Neuron production line. Each Unipi Patron ​or Neuron controller is shipped with Mervis RT license and login credentials for Mervis DB and Mervis Proxy services included in the package. For Unipi 1.1 or Unipi Gate the license has to be [[https://​www.unipi.technology/​mervis-p56|purchased separately]].
 </​WRAP>​ </​WRAP>​