 ====== Unipi Software ====== ====== Unipi Software ======
-This section ​includes topics related to Unipi software (repository,​ FW tools, etc.)+This article ​includes topics related to Unipi software (repository,​ FW tools, etc.)
  
 ===== APT Repository ==== ===== APT Repository ====
Line 8: Line 8:
  
 <WRAP center round info 90%> <WRAP center round info 90%>
-Currently, the packages are supported only for all controllers ​except Unipi 1.1 and Unipi 1.1. lite - those should be [[en:​sw:​02-apis:​01-evok|installed as described here.]]+Currently, the packages are supported only for all units except Unipi 1.1 and Unipi 1.1. lite - those should be [[en:​sw:​02-apis:​01-evok|installed as described here.]]
 </​WRAP>​ </​WRAP>​
  
Line 32: Line 32:
 The internal firmware is NOT automatically flashed to the latest version installed using apt. This has to be done manually. The internal firmware is NOT automatically flashed to the latest version installed using apt. This has to be done manually.
  
-=== Upgrading firmware in Neuron/​Axon ​family PLC controllers ​===+=== Upgrading firmware in Patron/Neuron/​Axon ​line units ===
 The firmware can be manually upgraded or checked using the fwspi tool which resides in /​opt/​unipi-bin/​ (newly in /​opt/​unipi/​tools/​). The firmware can be manually upgraded or checked using the fwspi tool which resides in /​opt/​unipi-bin/​ (newly in /​opt/​unipi/​tools/​).
  
-To check the firmware on the first group of IOs:+To check the firmware on the first section ​of IOs:
 <​code>​ <​code>​
 /​opt/​unipi/​tools/​fwspi -i 0 /​opt/​unipi/​tools/​fwspi -i 0
Line 41: Line 41:
  
 <WRAP center round info 60%> <WRAP center round info 60%>
-To check the FW of other IO groups ​run <​code>/​opt/​unipi/​tools/​fwspi -i 1</​code>​ alternatively <​code>/​opt/​unipi/​tools/​fwspi -i 2</​code>​.+To check the FW of other IO sections ​run <​code>/​opt/​unipi/​tools/​fwspi -i 1</​code>​ alternatively <​code>/​opt/​unipi/​tools/​fwspi -i 2</​code>​.
 </​WRAP>​ </​WRAP>​
  
 <WRAP center round info 60%> <WRAP center round info 60%>
-Firmware upgrade can be done automatically on all groups ​available using command <​code>/​opt/​unipi/​tools/​fwspi -v --auto</​code>​+Firmware upgrade can be done automatically on all sections ​available using command <​code>/​opt/​unipi/​tools/​fwspi -v --auto</​code>​
 </​WRAP>​ </​WRAP>​
  
Line 79: Line 79:
  
 <WRAP center round info 60%> <WRAP center round info 60%>
-The configuration of the group can be erased to the default state. This is done during the firmware upgrade by calling the fwspi utility also with -R parameter. E.g. /​opt/​unipi/​tools/​fwspi -i 0 -PR+The configuration of the section ​can be erased to the default state. This is done during the firmware upgrade by calling the fwspi utility also with -R parameter. E.g. /​opt/​unipi/​tools/​fwspi -i 0 -PR
 </​WRAP>​ </​WRAP>​
  
Line 86: Line 86:
  
 <WRAP center round alert 80%> <WRAP center round alert 80%>
-Make sure that there is no other application using/​communicating on the used port and do not disconnect power to the Controller ​or Extension. Any of this will lead to bricking the extension.+Make sure that there is no other application using/​communicating on the used port and do not disconnect power to the unit or Extension. Any of this will lead to bricking the extension.
 </​WRAP>​ </​WRAP>​
  
  
 <WRAP center round info 80%> <WRAP center round info 80%>
-The -p (path) parameter must be set according to the used serial for the extension - see the [[en:hw:01-axon:​portmap|]] ​or [[en:​hw:​02-neuron:​portmap|]]to find proper serial port within your unit. For example, if extension is connected to //​RS485-1/​RS485-1.1//:​ <​code>/​opt/​unipi/​tools/​fwserial -p /dev/ttyNS0 -P </​code>​.+The -p (path) parameter must be set according to the used serial for the extension - see the [[en:hw:007-patron:portmap|]][[en:​hw:​02-neuron:portmap|]] or [[en:​hw:​01-axon:portmap|]] to find proper serial port within your unit. For example, if extension is connected to //​RS485-1/​RS485-1.1//:​ <​code>/​opt/​unipi/​tools/​fwserial -p /dev/ttyNS0 -P </​code>​.
 Note that the fwserial assumes that extension‘s Modbus address, baud rate and parity are in the factory-default state, ie **19200 baud 8N1 with address 15**.  Note that the fwserial assumes that extension‘s Modbus address, baud rate and parity are in the factory-default state, ie **19200 baud 8N1 with address 15**. 