en:hw:05-sensors:1-wire-ds150b-hidden [2020/11/19 15:15] jan_kozak |
en:hw:05-sensors:1-wire-ds150b-hidden [2021/08/10 06:43] (current) avsetula |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | FIXME | ||
{{ :cs:hw:05-sensors:ds150b.png?direct&220|}} | {{ :cs:hw:05-sensors:ds150b.png?direct&220|}} | ||
* Designed for contact measurements of pipeline surface temperature (IP65 protection) | * Designed for contact measurements of pipeline surface temperature (IP65 protection) | ||
Line 6: | Line 5: | ||
* Holding metal band length: 40 cm | * Holding metal band length: 40 cm | ||
* Minimal pipe diameter: 20 mm | * Minimal pipe diameter: 20 mm | ||
- | * Temperature sensors are suitable for measuring temperature in the range of -10 °C to 85 °C. With reduced accuracy, the sensors can be used in a range of -40°C to 105°C. | + | * Temperature sensors are suitable for measuring temperature in the range of -10 °C to 85 °C. With reduced accuracy, the sensors can be used in a range of -30°C to 100°C. |
* Cable temperature range: -30 °C to 105 °C | * Cable temperature range: -30 °C to 105 °C | ||
* Suitable for all Unipi devices with a 1W bus -> 4-wire connection | * Suitable for all Unipi devices with a 1W bus -> 4-wire connection | ||
* Easy connection to the Extension xG18 via RJ45 connector | * Easy connection to the Extension xG18 via RJ45 connector | ||
- | * Can be connected to Unipi PLCs using [[https://www.unipi.technology/cables-reductions-hubs-c41|a splitter]] | + | * Can be connected to Unipi units using [[https://www.unipi.technology/cables-reductions-hubs-c41|a splitter]] |
* For more information and tips regarding the sensor connection, please visit the [[en:automation:02-glossary:1wire-hidden|1-Wire article]] | * For more information and tips regarding the sensor connection, please visit the [[en:automation:02-glossary:1wire-hidden|1-Wire article]] | ||
+ | * Link to e-shop [[https://www.unipi.technology/1-wire-sump-temperature-sensor-3-m-p394|link]] | ||
<html><span class="kbBlueText">Examples of use:</span></html> | <html><span class="kbBlueText">Examples of use:</span></html> | ||
Line 18: | Line 18: | ||
<html><span class="kbBlueText">Applicable for: </span></html> | <html><span class="kbBlueText">Applicable for: </span></html> | ||
- | * All Unipi PLCs with a 1W bus, including the Unipi 1.1/Lite | + | * All Unipi units with a 1W bus, including the Unipi 1.1/Lite |
* With Unipi 1W hub and splitter | * With Unipi 1W hub and splitter | ||
* Unipi Extension xG18 | * Unipi Extension xG18 | ||
- | A direct connection to Unipi PLC can be performed by cutting away the connector and connecting the sensor to the 1W terminal of Patron or Neuron controllers. Older Neuron controllers and the Unipi 1.1/Lite feature an RJ45 connector, allowing for a direct connection. For more info, please visit the [[en:automation:02-glossary:1wire-hidden#wire_bus_on_unipi_devices|1-Wire bus and sensor connection]]. | + | A direct connection to Unipi unit can be performed by cutting away the connector and connecting the sensor to the 1W terminal of Patron or Neuron units. Older Neuron units and the Unipi 1.1/Lite feature an RJ45 connector, allowing for a direct connection. For more info, please visit the [[en:automation:02-glossary:1wire-hidden#wire_bus_on_unipi_devices|1-Wire bus and sensor connection]]. |