Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:hw:05-sensors:1-wire-ds150b-hidden [2020/11/19 15:15]
jan_kozak
en:hw:05-sensors:1-wire-ds150b-hidden [2021/08/10 06:43] (current)
avsetula
Line 1: Line 1:
-FIXME 
 {{ :​cs:​hw:​05-sensors:​ds150b.png?​direct&​220|}} {{ :​cs:​hw:​05-sensors:​ds150b.png?​direct&​220|}}
   * Designed for contact measurements of pipeline surface temperature (IP65 protection)   * Designed for contact measurements of pipeline surface temperature (IP65 protection)
Line 6: Line 5:
   * Holding metal band length: 40 cm   * Holding metal band length: 40 cm
   * Minimal pipe diameter: 20 mm   * Minimal pipe diameter: 20 mm
-   * Temperature sensors are suitable for measuring temperature in the range of -10 °C to 85 °C. With reduced accuracy, the sensors can be used in a range of -40°C to 105°C+   * Temperature sensors are suitable for measuring temperature in the range of -10 °C to 85 °C. With reduced accuracy, the sensors can be used in a range of -30°C to 100°C
   * Cable temperature range: -30 °C to 105 °C   * Cable temperature range: -30 °C to 105 °C
   * Suitable for all Unipi devices with a 1W bus -> 4-wire connection   * Suitable for all Unipi devices with a 1W bus -> 4-wire connection
   * Easy connection to the Extension xG18 via RJ45 connector   * Easy connection to the Extension xG18 via RJ45 connector
-  * Can be connected to Unipi PLCs using [[https://​www.unipi.technology/​cables-reductions-hubs-c41|a splitter]]+  * Can be connected to Unipi units using [[https://​www.unipi.technology/​cables-reductions-hubs-c41|a splitter]]
   * For more information and tips regarding the sensor connection, please visit the [[en:​automation:​02-glossary:​1wire-hidden|1-Wire article]]   * For more information and tips regarding the sensor connection, please visit the [[en:​automation:​02-glossary:​1wire-hidden|1-Wire article]]
 +  * Link to e-shop [[https://​www.unipi.technology/​1-wire-sump-temperature-sensor-3-m-p394|link]]
  
 <​html><​span class="​kbBlueText">​Examples of use:</​span></​html>​ <​html><​span class="​kbBlueText">​Examples of use:</​span></​html>​
Line 18: Line 18:
  
 <​html><​span class="​kbBlueText">​Applicable for: </​span></​html>​ <​html><​span class="​kbBlueText">​Applicable for: </​span></​html>​
-  * All Unipi PLCs with a 1W bus, including the Unipi 1.1/Lite+  * All Unipi units with a 1W bus, including the Unipi 1.1/Lite
     * With Unipi 1W hub and splitter     * With Unipi 1W hub and splitter
   * Unipi Extension xG18   * Unipi Extension xG18
  
-A direct connection to Unipi PLC can be performed by cutting away the connector and connecting the sensor to the 1W terminal of Patron or Neuron ​controllers. Older Neuron ​controllers ​and the Unipi 1.1/Lite feature an RJ45 connector, allowing for a direct connection. For more info, please visit the [[en:​automation:​02-glossary:​1wire-hidden#​wire_bus_on_unipi_devices|1-Wire bus and sensor connection]].+A direct connection to Unipi unit can be performed by cutting away the connector and connecting the sensor to the 1W terminal of Patron or Neuron ​units. Older Neuron ​units and the Unipi 1.1/Lite feature an RJ45 connector, allowing for a direct connection. For more info, please visit the [[en:​automation:​02-glossary:​1wire-hidden#​wire_bus_on_unipi_devices|1-Wire bus and sensor connection]].