| Both sides previous revisionPrevious revisionNext revision | Previous revision |
| en:sw:01-mervis:multiple-unipi-through-sscp-hidden [2021/03/04 07:53] – [1 Basic project settings in Mervis IDE] avsetula | en:sw:01-mervis:multiple-unipi-through-sscp-hidden [2025/09/26 06:36] (current) – [1 Basic project settings in Mervis IDE] translate Czech text kcerny |
|---|
| <WRAP half column 15%> | <WRAP half column 15%> |
| ;;# | ;;# |
| <html><span class="dev-tag dev-axon">Axon</span></html> \\ | <html><span class="dev-tag dev-patron">Patron</span></html> \\ |
| <html><span class="dev-tag dev-neuron">Neuron</span></html> \\ | <html><span class="dev-tag dev-neuron">Neuron</span></html> \\ |
| <html><span class="dev-tag dev-unipi11">Unipi 1.1</span></html> | <html><span class="dev-tag dev-gate">Gate</span></html> \\ |
| | <html><span class="dev-tag dev-unipi11">Unipi 1.1</span></html> \\ |
| | <html><span class="dev-tag dev-axon">Axon</span></html> |
| ;;# | ;;# |
| </WRAP> | </WRAP> |
| </WRAP> | </WRAP> |
| |
| ==== Prerequisites ==== | <WRAP center round box> |
| | <html><span class="kbBlue-H4alt">Prerequisites:</span></html> |
| * Two [[https://www.unipi.technology/axon-c20|Unipi]] controllers running [[en:files:software:os-images:00-start|Mervis OS]] | * Two [[https://www.unipi.technology/axon-c20|Unipi]] controllers running [[en:files:software:os-images:00-start|Mervis OS]] |
| * [[https://www.unipi.technology/accessories-c4|24V DC power supply]] | * [[https://www.unipi.technology/accessories-c4|24 V⎓ power supply]] |
| * Local network connectivity (any switch or router)) | * Local network connectivity (any switch or router)) |
| * 3× network cable (RJ45) | * 3× network cable (RJ45) |
| | </WRAP> |
| |
| ===== 1 Basic project settings in Mervis IDE ===== | ===== 1 Basic project settings in Mervis IDE ===== |
| </figure></html> | </figure></html> |
| |
| Create the project in Simple Mode and then [[https://kb.unipi.technology/en:sw:01-mervis:creating-new-project-hidden#switching_from_simple_mode_to_full_mode|switch it to Full Mode]]. Then connect the first PLC to the project by right-clicking on <html><span class="avBlueText">PLC</span></html> and selecting <html><span class="avBlueText">Attach PLC</span></html>. | Create the project in Simple Mode and then [[en:sw:01-mervis:creating-new-project-hidden#switching_to_full_mode|switch it to Full Mode]]. Then connect the first PLC to the project by right-clicking on <html><span class="avBlueText">PLC</span></html> and selecting <html><span class="avBlueText">Attach PLC</span></html>. |
| |
| <html><figure ondblclick="redirectImg(this)" class="zoom" onclick="zoom(event)" style="background-image: url(https://kb.unipi.technology/_media/cs:sw:01-mervis:002_multiple-unipi-through-sscp-cz.png)"> | <html><figure ondblclick="redirectImg(this)" class="zoom" onclick="zoom(event)" style="background-image: url(https://kb.unipi.technology/_media/cs:sw:01-mervis:002_multiple-unipi-through-sscp-cz.png)"> |
| </figure></html> | </figure></html> |
| |
| | <html><div class="directTag" id="set-task"></div></html> |
| Double-click on <html><span class="avOrangeText">PLC_Slave</span></html> to open its properties. Right-click into the blank space to display a context menu, in which select <html><span class="avBlueText">Add Task</span></html>. | Double-click on <html><span class="avOrangeText">PLC_Slave</span></html> to open its properties. Right-click into the blank space to display a context menu, in which select <html><span class="avBlueText">Add Task</span></html>. |
| |
| Name the device <html><span class="avOrangeText">slave_PLC</span></html>, select it and look into the right panel <html><span class="avBlueText">Properties</span></html>. In <html><span class="avBlueText">SSCP device parameters</span></html> you need to select <html><span class="avBlueText">Source substation</span></html> and <html><span class="avBlueText">Custom</span></html> endpoint. By doing so another configuration will be displayed. All necessary info can be found in PLC properties. For communication with the local network enter the following parameters: | Name the device <html><span class="avOrangeText">slave_PLC</span></html>, select it and look into the right panel <html><span class="avBlueText">Properties</span></html>. In <html><span class="avBlueText">SSCP device parameters</span></html> you need to select <html><span class="avBlueText">Source substation</span></html> and <html><span class="avBlueText">Custom</span></html> endpoint. By doing so another configuration will be displayed. All necessary info can be found in PLC properties. For communication with the local network enter the following parameters: |
| |
| <html><span class="kbBlueText">Parametry TCP:</span></html> | <html><span class="kbBlueText">TCP parameters:</span></html> |
| * **Device address:** Enter the IP address/domain | * **Device address:** Enter the IP address/domain |
| * **Device port:** 12346 | * **Device port:** 12346 |
| It is also possible for two PLCs to communicate through SSCP over vast distances. In this case, you also need to configure <html><span class="avBlueText">proxy</span></html> on <html><span class="avOrangeText">PLC_Slave</span></html>. | It is also possible for two PLCs to communicate through SSCP over vast distances. In this case, you also need to configure <html><span class="avBlueText">proxy</span></html> on <html><span class="avOrangeText">PLC_Slave</span></html>. |
| |
| If you want to use the proxy and it is already configured on the said PLC, adjust the following paramaters of the <html><span class="avOrangeText">SSCP_TCP</span></html> channel: | ---- |
| | |
| | <WRAP center round info> |
| | If you want to use the proxy and it is already configured on the said PLC, adjust the following paramaters of the <html><span class="avOrangeText">SSCP_TCP</span></html> channel: |
| | </WRAP> |
| | |
| |
| <html><span class="kbBlueText">TCP Parameters:</span></html> | <html><span class="kbBlueText">TCP Parameters:</span></html> |
| |
| <html><span class="kbBlueText">SSCP Device Parameters:</span></html> | <html><span class="kbBlueText">SSCP Device Parameters:</span></html> |
| * **Proxy ID:** vaše unikátní [[https://www.unipi.technology/getmervis|Proxy ID from the Unipi customer account]] | * Your unique **Proxy ID:** [[https://www.unipi.technology/getmervis|Proxy ID from the Unipi customer account]] |
| |
| Proxy connection variant is not recommended for control. It is, however, useful for collecting data (ie. temperatures) from multiple controllers into a single PLC for further use. | Proxy connection variant is not recommended for control. It is, however, useful for collecting data (ie. temperatures) from multiple controllers into a single PLC for further use. |
| </figure></html> | </figure></html> |
| |
| The next step is to use <html><span class="avBlueText">Autogen</span></html>, to create variables for data points. Right-click on each <html><span class="avBlueText">device</span></html> for each<html><span class="avBlueText">channel</span></html> and select <html><span class="avBlueText">set Autogen</span></html>. More info about Autogen is availabl [[autogen-hidden|here]]. | The next step is to use <html><span class="avBlueText">Autogen</span></html>, to create variables for data points. Right-click on each <html><span class="avBlueText">device</span></html> for each <html><span class="avBlueText">channel</span></html> and select <html><span class="avBlueText">set Autogen</span></html>. More info about Autogen is availabl [[autogen-hidden|here]]. |
| |
| <html><figure ondblclick="redirectImg(this)" class="zoom" onclick="zoom(event)" style="background-image: url(https://kb.unipi.technology/_media/cs:sw:01-mervis:019_multiple-unipi-through-sscp-cz.png)"> | <html><figure ondblclick="redirectImg(this)" class="zoom" onclick="zoom(event)" style="background-image: url(https://kb.unipi.technology/_media/cs:sw:01-mervis:019_multiple-unipi-through-sscp-cz.png)"> |