Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:sw:01-mervis:set-time-date-timezone-hidden [2020/03/18 11:52]
avsetula
en:sw:01-mervis:set-time-date-timezone-hidden [2021/05/03 09:37] (current)
avsetula
Line 1: Line 1:
-<​html>​ 
-  <​style>​ 
-    span.avBlueText{ 
-      font-weight:​ bold; 
-      color: #2f5496; 
-    } 
-    ​ 
-    span.avOrangeText{ 
-      font-weight:​ bold; 
-      color: #c45911; 
-    }    ​ 
-    ​ 
-     ​span.wrongTranslate{ 
-      font-weight:​ bold; 
-      background: #bb2922; 
-      color: #fff; 
-    }  
-    ​ 
-    span.kbBlueText{ 
-      font-weight:​ bold; 
-      text-decoration:​ underline; 
-      color: #00679a; 
-    } 
-  </​style>​ 
-</​html>​ 
- 
 ====== Configuration of date, time and timezone ====== ====== Configuration of date, time and timezone ======
-All Unipi PLCs feature Real Time Clock module (RTC) that are used mainly for the control of various time programs. All RTC clocks has a battery as a back-up, time settings are thus not affected by power outages. That said, it is still necessary to check now and then, if the settings are correct. ​+<WRAP group> 
 +<WRAP half column 81%> 
 +All Unipi PLCs feature Real Time Clock module (RTC) that are used mainly for the control of various time programs. All RTC clocks has a battery as a back-up, time settings are thus not affected by power outages. That said, it is still necessary to check now and then, if the settings are correct. 
 +</​WRAP>​ 
 +<WRAP half column 15%> 
 +;;# 
 +<​html><​span class="​dev-tag dev-patron">​Patron</​span></​html>​ \\ 
 +<​html><​span class="​dev-tag dev-neuron">​Neuron</​span></​html>​ \\ 
 +<​html><​span class="​dev-tag dev-gate">​Gate</​span></​html>​ \\ 
 +<​html><​span class="​dev-tag dev-unipi11">​Unipi&​nbsp1.1</​span></​html>​ \\ 
 +<​html><​span class="​dev-tag dev-axon">​Axon</​span></​html>​ 
 +;;# 
 +</​WRAP>​ 
 +</​WRAP>​
  
 ==== Manual setup ==== ==== Manual setup ====
Line 32: Line 19:
 Right-click on <​html><​span class="​avBlueText">​PLC</​span></​html>​ -> <​html><​span class="​avBlueText">​PLC Operations</​span></​html>​ -> <​html><​span class="​avBlueText">​PLC Setup</​span></​html>​ -> <​html><​span class="​avBlueText">​Time setup</​span></​html>​. ​ Right-click on <​html><​span class="​avBlueText">​PLC</​span></​html>​ -> <​html><​span class="​avBlueText">​PLC Operations</​span></​html>​ -> <​html><​span class="​avBlueText">​PLC Setup</​span></​html>​ -> <​html><​span class="​avBlueText">​Time setup</​span></​html>​. ​
  
-{{ :cs:​sw:​01-mervis:​01_timeset_cs.png?direct |obrázek 01}}+{{ :en:​sw:​01-mervis:​01_timeset_en.png?direct |Img01}}
  
 \\ \\
 Here, you can update the PLC time according to the time in you PC, or you can set your own time. In both cases the time is converted to UTC time based on the time zone set for the PLC.  Here, you can update the PLC time according to the time in you PC, or you can set your own time. In both cases the time is converted to UTC time based on the time zone set for the PLC. 
  
-{{ :cs:​sw:​01-mervis:​02_timeset_cs.png?​direct&​400 |obrázek 02}}+{{ :en:​sw:​01-mervis:​02_timeset_en.png?​direct&​400 |Img02}}
  
 \\ \\
Line 44: Line 31:
 if the PLC is connected to a network with Internet access, you can sync the time using any available NTP server. Some industrial networks even include their own internal NTP servers to allow time synchronization without the need for internet connection. Ask your network administrator for detailed info.  if the PLC is connected to a network with Internet access, you can sync the time using any available NTP server. Some industrial networks even include their own internal NTP servers to allow time synchronization without the need for internet connection. Ask your network administrator for detailed info. 
  
-Time sync through an NTP server is done each day at 3:15 AM. NTP server can be configured in PLC properties. Click on <​html><​span class="​avBlueText">​PLC</​span></​html>​ and in the **right panel**, select the <​html><​span class="​avBlueText">​Date/​Time Settings</​span></​html>: ​+Time sync through an NTP server is done each day at 3:15 AM. NTP server can be configured in PLC properties. Click on <​html><​span class="​avBlueText">​PLC</​span></​html>​ and in the <​html><​span class="​avBlueText">​right panel</​span></​html>​, select the <​html><​span class="​avBlueText">​Date/​Time Settings</​span></​html>: ​
  
-{{ :cs:​sw:​01-mervis:​03_timeset_cs.png?​direct&​500 |}}+{{ :en:​sw:​01-mervis:​03_timeset_en.png?​direct&​500 |}}
  
 \\ \\
Line 59: Line 46:
  
 \\ \\
-{{ :cs:​sw:​01-mervis:​04_timeset_cs.png?​direct&​450 |}}+{{ :en:​sw:​01-mervis:​04_timeset_en.png?​direct&​450 |}}