• Variant with the sensor placed in a metal probe (IP67)
  • Digital waterproof 1W sensor with a DS18B20 chip
  • Probe dimensions: ⌀5,7* x 40 mm (±0,1mm*)
  • Temperature sensors are suitable for measuring temperature in the range of -10 °C to 85 °C. With reduced accuracy, the sensors can be used in a range of -40°C to 105°C.
  • Cable temperature range: -30 °C to 105 °C
  • Suitable for all Unipi devices with a 1W bus → 4-wire connection
  • Easy connection to the Extension xG18 via RJ45 connector
  • Can be connected to Unipi units using a splitter
  • For more information and tips regarding the sensor connection, please visit the 1-Wire article
  • Link to e-shop link

Examples of use:

  • Measuring indoor or outdoor temperature for the purpose of heating control
  • When placed into a thermowell, the sensor can be used to measure the temperature of media in pipelines or tanks (it is possible to place multiple sensors in different levels for more accurate readings)
  • The method of use must be selected in accordance with the temperature and chemical durability of the probe and the input cable

Applicable for:

  • All Unipi units with a 1W bus, including the Unipi 1.1/Lite
    • With Unipi 1W hub and splitter
  • Unipi Extension xG18

A direct connection to Unipi unit can be performed by cutting away the connector and connecting the sensor to the 1W terminal of Patron or Neuron units. Older Neuron units and the Unipi 1.1/Lite feature an RJ45 connector, allowing for a direct connection. For more info, please visit the 1-Wire bus and sensor connection.